  1. Stryker Prime Series stretchers. Extraordinarily mobile and user-friendly, Stryker Prime Series stretchers are designed to greatly reduce the physical strain on clinicians while enhancing patient care and comfort.
  2. Feedback; Login to access TechWeb (Only for Stryker Users) Home Stretcher 1105 1308 1105 5th Wheel Prime Series Stretcher (1308xxxxx - Current) Technical Product Information Chest Compression Devices. CHG Hospital Beds. Manuals-Operation Language Size Description 1105-309-001; English: 27.34 MB: 1105-409-005.
  3. 1105 5th Wheel Prime Series Stretcher - through 1308xxxxx Launch of PrimeX (X-Ray trauma option) and accessories foot end push handles and foot supports. Starting with serial number the caster force was enhanced which was revised into the design, the last serial number prior to the change was.
  4. Includes new mattress. Advanced Mobility Options Stryker Prime offers three advanced mobility options – the Zoom Motorized Drive System that virtually eliminates manual push force; the Big Wheel that can reduce push force by 50% and steering effort by 60%;.
  1. Stryker Prime Series Service Manual
  2. Stryker 1105 Prime Series Manual
  3. Stryker Prime Series
  4. Stryker 1105 Prime Series Service Manual
  5. Stryker 1105 Prime Series User Manual Windows
One moment please..

Stryker 1105 Prime Series Stretcher Prices Refurbished Price = $2,395 – includes new mattress pad Reconditioned Price = $3,195 – includes new mattress pad. The Prime Series stretcher with retractable fifth wheel is intended to steer the stretcher along a straight. Four-sided brakes offer convenient access, while a power-washable design makes Prime Series Stretchers easy to clean in a fast-paced healthcare environment. Glideaway Siderails These siderails offer maximum patient security when raised, yet are completely.

View and Download Chef's Choice 250 instruction manual online. Hybrid Diamond Hone. 250 Accessories pdf manual download. Accessories Chef's Choice Chef`sChoice 463 User Manual. Knife sharpener for asian knives (2 pages). As described later in more detail, the Model 250 Hybrid. Chef's choice hybrid 250 user manual.

DESCRIPTION
Mobile. Safe. Efficient.

Stryker Prime is designed to ensure caregiver safety and efficiency while enhancing the patient experience. Prime is BackSmart. It can be instrumental in reducing caregiver injuries during patient care. Prime offers three mobility options and unprecedented patient comfort. Patients can adjust their own positions without calling a caregiver for assistance. A variety of available support surfaces and configuration options give Prime the versatility you need. The 700 lb weight capacity combined with multiple mobility solutions help accommodate heavy patients and long transports. Power and control options give more flexibility and control than ever to both nurse and patient. A choice of available surfaces addresses patient comfort and skin issues associated with extended lengths of stay, helping maintain a positive patient experience.


  1. 1105: All Standard Features Plus Fifth Wheel steering
  2. 1115: All Standard Features Plus Big Wheel steering
  3. 1125: All Standard Features Plus Zoom Motorized Drive System
FORUMSView All (11)

Stryker Prime Series Service Manual

Ask a New Question

0

Replies
-cdharris22
2 years ago
2 years agoPrime 1125 PM Check List
Preventative maintenance should be performed at a minimum of annually. A preventative maintenance program shouldbe established for all Stryker Medical equipment. Preventative maintenance may need to be performed more frequentlybased on the usage level of the product.CHECKLIST_____ All fasteners secure_____ Siderails move and latch properly_____ All casters lock with brake pedal engaged_____ All casters secure and swivel properly_____ Inspect each caster and remove any wax or debris which may have collected on the caster or brakingmechanism_____ Steer function working properly_____ Fowler operates and latches properly_____ Gatch operating properly (Optional equipment)_____ Trendelenburg/reverse Trendelenburg operates properly_____ Ground chain intact_____ No leaks at hydraulic connections_____ Hydraulic jacks holding properly_____ Hydraulic oil level sufficient_____ Lubricate where required_____ Body restraints working properly_____ I.V. pole intact and operates properly_____ Oxygen bottle holder intact and operates properly_____ No rips or cracks in mattress cover_____ Accessories and mounting hardware in good condition and working properly_____ No excessive play in the drive handles_____ Press the handle switches - unit should not move unless the handles are pushed forward or pulled back_____ Press the handle switches - move the handles forward and back and verify the unit responds properly_____ Confirm battery powered functionality_____ No cables worn, pinched or frayed_____ Power cord and plug are free of damage_____ All electrical connections tight_____ All grounds secure to the frame_____ Ground impedance not more than 200 m© (milliohms) max: Test point(s) include electronics enclosure andmotor chassis mounted to base of unit_____ Current leakage not more than 300 ¼A (microamps) (per UL 60601-1)_____ Batteries sufficiently charged (Optional scale system)_____ Display housing intact and not damaged (Optional scale system)_____ Load cells intact and not damaged (Optional scale system)_____ Scale calibrated properly. Recalibrate, if necessary (Optional scale system)Reply
-BPeardon
3 years ago
3 years ago1105 stretcher deck will not lay flat
Reply

3

Replies
-Larry Goodin
4 years ago
4 years agoChanging battery

Inspiron 17 7000 user manual. Where is the battery on this stretcher, what battery is used, and how do I change it?

Reply
DOCUMENTS / MANUALSView All


FEATURES

  • Advanced mobility, with optional Big Wheel or Zoom Motorized Drive System, helps make transport safe and efficient
  • Electric-powered base and litter option available on all mobility solutions
  • Stretcher exit system, alerts the nurse to a potential patient fall
  • Optional integrated scale system provides accurate,repeatable weighing
  • Pioneer mattress offers superior pressure redistribution and comfort
  • Power-washable design with 700 lb capacity
SERIES MODELS

Stryker 1105 Prime Series Manual

Patient Weight Capacity700 lbs
Height34 in High, Low 20.75
Length 85 in
Width34 in with siderails up
Additional SpecificationsLitter Positioning:
Backrest- 0°– 90°
Knee Gatch- 0°– 40°
Trend./Reverse Trend.(1105 and 1115)-±17°
Trend./Reverse Trend.(1125)-±16°
Maximum Angle- 87.5°
Patient Surface: 26' x 75.25' (66 x 191 cm)
Siderails: 14' x 57.75' (36 x 147 cm)
Caster Diameter: 8' (20 cm)
Patient Weight Capacity700 lbs
Height34 in High
Length 85 in to 86'
Width38 in with siderails up
Additional Specifications30' Litter
Overall Length:
(1105 and 1115)-85' (216 cm)
(1125)-86' (218 cm)
Overall Width:
Siderails Up- 38' (96.5 cm)
Siderails Down (1105 and 1115)- 30.5' (77.5 cm)
Siderails Down (1125)-31' (78.7 cm)
Weight Capacity: 700 lbs (318 kg)
Height Range:
High- 34' (86.4 cm)
Low (1105 and 1115)- 20.75' (53 cm)
Low (1125)- 23' (58 cm)
Litter Positioning:
Backrest- 0°– 90°
Knee Gatch- 0°– 40°
Trend./Reverse Trend.(1105 and 1115)-±17°
Trend./Reverse Trend.(1125)-±16°
Maximum Angle- 87.5°
Patient Surface: 30' x 75.25' (76 x 191 cm)
Siderails: 14' x 57.75' (36 x 147 cm)
Caster Diameter: 8' (20 cm)
NEWSView All
Product Showroom: Hospital Beds

Stryker Prime Series

Stryker Prime Series stretchers. Extraordinarily mobile and user-friendly, Stryker Prime Series stretchers are designed to greatly reduce the physical strain on clinicians while enhancing patient care and comfort.

-
510(k)DeNovoRegistration & ListingAdverse EventsRecallsPMAHDEClassificationStandards
CFR Title 21Radiation-Emitting ProductsX-Ray AssemblerMedsun ReportsCLIATPLC

Stryker 1105 Prime Series Service Manual


Stryker 1105 Prime Series User Manual Windows

New SearchBack to Search Results
Class 2 Device Recall Stryker Medical 1105 Prime 5th Wheel
Date Initiated by FirmJuly 19, 2011
Date PostedAugust 03, 2011
Recall Status1Terminated 3 on August 28, 2013
Z-2927-2011
Recall Event ID59214
Stretcher, wheeled, powered - Product CodeINK
ProductStryker Medical Stretcher Model 1105 Prime 5th Wheel
A wheeled stretcher consists of a platform mounted on a wheeled frame that is designed to transport patients in a horizontal position. The device has siderails and supports for fluid infusion equipment.
Code InformationLots 1104032654, 1104030037, 1104030100, 1104030101, 1104030102, 1104030103, 1104030116, 1104032614, 1104032587, 1104032588, 1104032545, 1104032546, 1104032547, 1104032548, 1104032549, 1104030030, 1104030055, 1104030210 and 1104032611.
Recalling Firm/
Manufacturer
Stryker Medical Division of Stryker Corporation
3800 East Centre Ave.
Portage MI 49002
For Additional Information ContactMatt Jordan
269-389-6604
Stryker Medical has determined that some Prime Brake Pad Assembly components were manufactured with brake shoes that did not meet specifications. Accordingly some brake shoes used within the Prime Brake Pad Assembly may wear prematurely, over the life of the product. Reduced braking force may result in a patient fall or caregiver muscle strain, either of which may require medical intervention.
Nonconforming Material/Component
Stryker Medical sent an 'URGENT- MEDICAL DEVICE CORRECTION' letter dated July 18, 2011 to all affected customers. The letter identifies the product, problem, and actions to be taken by the customers. The letter instructs customers to locate the affected stretchers and to test the brakes. If the brakes are found to be inoperable, customers are instructed to remove the stretchers from service and contact the firm at 800-STRYKER, option 3. Additionally, customers are instructed not to put the stretchers back in service until they are repaired by the firm's field service representative. For units with properly functioning brakes, the letter also instructs the user to test the brakes before each use until the unit has been serviced. A post card was enclosed to confirm receipt of the letter. Questions or concerns may be addressed by calling Stryker at 269-389-6604.
23
Worldwide Distribution-USA (nationwide) including the states of AL, CA, FL, GA, HI, IL, MA, MN, MO, NH, NJ, NV, NY, PA, RI, TX, UT, and VA and the country of THE NETHERLANDS.
TPLC Device Report
1 A record in this database is created when a firm initiates a correction or removal action. The record is updated if the FDA identifies a violation and classifies the action as a recall, and it is updated for a final time when the recall is terminated. Learn more about medical device recalls.
2 Per FDA policy, recall cause determinations are subject to modification up to the point of termination of the recall.
3 For details about termination of a recall see Code of Federal Regulations (CFR) Title 21 §7.55.