The ZEISS Stratus OCT Model 3000 (Stratus OCT) enables examination of the posterior pole of the eye at an extremely fine spatial scale, without surgical biopsy or even any contact with the eye.

  1. Zeiss Stratus Oct 3000
  2. Stratus Oct Model 3000 User Manual Free
  3. Stratus Oct Model 3000 User Manual 2016
  4. 2004 Dodge Stratus Manual Pdf
  5. Stratus Oct Training
  6. Stratus Oct 3000 User Manual

The name Stratus OCT (derived from “stratum,” Latin for “layer”) refers to its unique ability of direct cross-sectional imaging of the layers of the retina. The Stratus OCT minimizes patient discomfort as it permits detailed examination of the retina and optic nerve head at the office or clinic. The Stratus OCT facilitates diagnosis and management of retinal diseases and glaucoma.

Zeiss Stratus Oct 3000

Stratus Oct Model 3000 User Manual OCT Stratus V. 7.0 demonstration Carl Zeiss Stratus OCT 3000 Optical Coherence. Zeiss Stratus OCT 3000. This unit includes the Zeiss Stratus OCT, The Stratus OCT table, Computer, Printer and all Months Warranti, Oct Tables, Associ Zeiss, Oct 3000, Stratus, Oct Avail, Fully. Zeiss Stratus OCT 3000 Manuals & User Guides. User Manuals, Guides and Specifications for your Zeiss Stratus OCT 3000 Medical Equipment. Database contains 1 Zeiss Stratus OCT 3000 Manuals (available for free online viewing or downloading in PDF): Service manual. Table 1-1 Combinations of DICOM Service Providers that enable Stratus OCT to integrate as Acquisition Modality Modality Worklist SCP Encapsulated PDF Storage Raw Data Storage OPT Image Storage g Commitment Push Model SOP Study Root Q/R. Is transforming workflow efficiency. The fully automatic and manual registration of ZEISS CIRRUS HD-OCT. Used CARL ZEISS Cirrus 4000 HD OCT For Sale - DOTmed Listing #1714167: Zeiss Cirrus 4000 Spectral Domain OCT This device is User's Manual (PDF) Zeiss Stratus Oct 3000 Service Repair Manual vs Service Manual Popular Posts Carl Zeiss.

Intended Use

The Stratus OCT is intended for use as a diagnostic device to aid in the management of ocular diseases.

Indications for Use

The Stratus OCT is a non-contact, high resolution tomographic and biomicroscopic imaging device. It is indicated for in vivo viewing and axial cross-sectional imaging and measurement of posterior ocular structures, including retina, retinal nerve fiber layer, macula, and optic disc. It is intended for use as a diagnostic device to aid in the detection and management of ocular diseases including, but not limited to, macular holes, cystoid macular edema, diabetic retinopathy, age-related macular degeneration and glaucoma.

Stratus OCT System Described

The Bank Directory must contain the master data of all banks that you require for payment transactions with your business partners. This course will focus on how SAP Bank accounting module manages bank transactions and activities.The starting point of the course will introduce the concept of Bank Master Record’s creation and will give explanations with regards as to how they will relate to transactional processes. The course will also touch on the structures of Bank Accounting record and their significance to processes that are critical to bank accounting in the recording of accounting transactions such as bank reconciliations.In SAP, the bank master record is stored centrally in the Bank Directory. This includes your banks and banks of your business partners (both domestic and foreign banks). Manual

The Stratus OCT is a computer-assisted precision optical instrument that generates cross sectional images (tomograms) of the retina with ≤ 10 micrometers axial resolution. It works by using an optical measurement technique known as low-coherence interferometry.

How The Stratus OCT Works

Stratus Oct Model 3000 User Manual Free

The principle of operation of interferometry is analogous to ultrasound, except that it uses light rather than sound. The difference permits measurement of structures and distances on the ≤ 10 micrometer scale, versus the 100-micrometer scale for ultrasound. Another important difference is that optical interferometry does not require contact with the tissue examined, unlike ultrasound.

The Stratus OCT contains an interferometer that resolves retinal structures by measuring the echo delay time of light that is reflected and backscattered from different microstructural features in the retina. The Stratus OCT projects a broad bandwidth near-infrared light beam (820 nm) onto the retina from a super luminescent diode. It then compares the echo time delays of light reflected from the retina with the echo time delays of the same light beam reflected from a reference mirror at known distances. When the Stratus OCT interferometer combines the reflected light pulses from the retina and reference mirror, a phenomenon known as interference occurs. A photodetector detects and measures interference. Although the light reflected from the retina consists of multiple echoes, the distance traveled by various echoes is determined by varying the distance to the reference mirror. This produces a range of time delays of the reference light for comparison.

The Stratus OCT interferometer electronically detects, collects, processes and stores the echo delay patterns from the retina. With each scan pass, the Stratus OCT captures from 128 to 768 longitudinal (axial) range samples, i.e., A-scans. Each A-scan consists of 1024 data points over 2 mm of depth. Thus the Stratus OCT integrates from 131,072 to 786,432 data points to construct a cross sectional image (tomogram) of retinal anatomy. It displays the tomograms in real time using a false color scale that represents the degree of light backscattering from tissues at different depths in the retina. The system stores the scans you select for later analysis.
How It Works for You

Stratus Oct Model 3000 User Manual 2016

The Stratus OCT delineates intraretinal, cross-sectional anatomy with axial resolution of ≤10 micrometers and transverse resolution of 20 micrometers. The Stratus OCT software package includes 19 scan acquisition protocols and 19 analysis protocols. Together they enable you to analyze the optic disc, retinal nerve fiber layer and the macula with a single instrument. The Stratus OCT facilitates the evaluation of both glaucoma and vitreoretinal disease. The Stratus OCT video camera enables you to view the patient’s fundus as you work, and to store video and scan images together. The data management system enables you to keep Stratus OCT histories, so you can monitor patients over time. You can archive images and data on rewritable DVD-RAM disks. The inkjet printer enables you to generate color hard copy.

Stratus OCT System Hardware
The Stratus OCT system hardware consists of the Patient Module; the Computer Unit; the Flat Screen Video Monitor; the keyboard, mouse and color inkjet printer. The hardware mounts on a wheelchair accessible motorized power table. The table accommodates elevation adjustment to each patient’s height. The illustration below labels hardware elements.

Stratus OCT Detials

The Stratus OCT incorporates optical coherence tomography technology to provide comprehensive imaging and measurement of glaucoma and retinal disease. Stratus OCT is the gold standard in vivo imaging device for the posterior segment and offers proven reproducibility for disease management.

The Stratus OCT provides real-time cross-sectional images and quantitative analysis of retinal features to optimize the diagnosis and monitoring of retinal disease and for enhanced pre- and post-therapy assessment. The device is beneficial for evaluation of cataract patients, pre- and post-operatively, and for the assessment of early signs of glaucoma and glaucomatous change.

Retinal Nerve Fiber Layer (RNFL) Analysis

Circular scans around the optic nerve head capture RNFL measurement of the peripapillary region. Analyses provide comparison of measurements to a normative database, demonstration of asymmetry and serial analysis.

Optic Nerve Head Analysis

To ensure proper placement of the drawer, pull out fully. You will hear a clicking sound that indicates the rails have engaged. The drawer should be fully engaged and the rails locked in place. Amana front load washer user manual.

Radial line scans through the optic disc create cross-sectional and topographical data. The key analysis parameters include cup-to-disc ratios and horizontal integrated rim volume.

Macular Thickness Analysis

Radial line scans provide cross-sectional images and analyses revealing retinal layers and macular condition. The change analysis feature illustrates change over time.

Specifications

  • Tomographic Imaging
  • Purpose: Cross sectional imaging of fundus
  • Signal Type: Optical scattering from tissue
  • Signal source: Super Luminescent Diode (SLD), 820 nm
  • Optical Power: ≤ 750 microwatts at cornea. SLD current will shut off if a safety circuit is activated (upon scanner failure)
  • Spot Size at Retina: 20 μm in tissue
  • Longitudinal/Axial Resolution: ≤ 10 μm in tissue
  • Transverse Resolution: 20 μm in tissue
  • Scanners: Galvanometric mirrors
  • Scan Patterns: Repeat, Line, Circle, Raster Lines, Cross Hair, Radial Lines, Macular Thickness Map, Optic Disc, Proportional Circle, Concentric 3 Rings, RNFL Thickness (3.4), Nerve Head Circle, RNFL Thickness (2.27xdisc), X-Line, RNFL Map, Fast Macular Thickness Map, Fast Optic Disc, Fast RNFL Thickness (3.4), Fast RNFL Map
  • Scan Pixels: Adjustable from 131,072 to 786,432 (1024 longitudinal x 128 to 768 transverse)
  • Scan Speed: 400 A-scans per second
  • Scan Acquisition Time: Approx. 0.32 seconds (128 A-scans minimum.) to approx. 1.92 seconds (768 A-scans maximum.)
  • Longitudinal (Depth) Scan Range: 2 mm in tissue

Description

Specifications for Stratus OCT

This is NOT old technology! Stratus gives you the same basic information and receives the same reimbursement, with the exception of anterior segment imaging.

Stratus OCT provides a higher level of diagnostic insight – a significant contribution to therapeutic confidence across a broad spectrum of ophthalmic diseases. Using near-infrared frequency light, Stratus OCT reveals an in vivo crosssectional view with an axial resolution of 10 μm, and quantitative analysis of the retinal layers.

In the Stratus OCT image display, retinal layers with the highest reflectivity appear red. In a healthy retina, these include the nerve fiber layer, retinal pigment epithelium and choriocapillaris. The layers that exhibit minimal reflectivity appear blue or black, such as the photoreceptor layer, choroid, vitreous fluid or blood.

Obtain real-time non-invasive histology of live tissue.

Stratus OCT reveals the retinal layers in high-resolution, cross-sectional views, offering insight for diagnosis,
therapy and ongoing management of retinal disorders.

Visualize and analyze retinal disorders.

Diabetic Retinopathy
  • Stratus OCT reveals and measures diffuse macular thickening and loss of foveal contour
  • Intraretinal cysts and fluid accumulation are identifiable as areas of low reflectivity in the cross-sectional scan
  • Post-treatment resolution of retinal thickening can be quantified and monitored
Epiretinal Membrane

2004 Dodge Stratus Manual Pdf

  • Stratus OCT scan shows the epiretinal membrane as a highly reflective band on the inner retinal surface
  • Separation of the membrane from the retina is visible in areas
  • Underlying retina is thickened, with loss of normal foveal contour
Age-related Macular Degeneration
  • Disruption of RPE, caused by neovascularization and drusen, can be visualized
  • Pockets of interretinal fluid are visible as areas of reduced reflectivity
  • Structural changes resulting from therapy can be quantified and monitored

Stratus Oct Training

Detect glaucoma damage at an early stage

Stratus Oct Model 3000 User Manual
Retinal Nerve Fiber Layer Analysis
  • Analysis of RNFL aids in identification of early glaucomatous loss
  • Circular scans of 3.4 mm diameter around optic nerve head provide measurement of RNFL in the peripapillary region
  • RNFL thickness measurement is graphed in a TSNIT orientation and compared to age-matched normative data
Optic Nerve Head Analysis
  • Radial line scans through optic disc provide crosssectional information on cupping and neuroretinal rim area
  • Disc margins are objectively identified using signal from end of RPE
  • Key parameters include cup-to-disc ratio and horizontal integrated rim volume1

Stratus Oct 3000 User Manual

Macular Thickness Analysis
  • Thinning of the macula may reflect glaucomatous loss
  • Structural analysis of retinal sublayers reveals macular complications
  • Cross-sectional view provides visualization and measurement of retinal layers

More information: